skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Jessup, Cody"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract We explore possible advantages of cyclic spectroscopy for observations of pulsars in instances where full cyclic deconvolution is not possible. We compute cyclic merits and full-deconvolution regime boundaries for pulsars observed by NANOGrav and discuss which sources stand to benefit the most from using cyclic spectroscopy when observed with the Green Bank Telescope and DSA-2000 in a given frequency range. We compare data products, namely the wavefield, in both full-deconvolution and partial-deconvolution regimes to demonstrate what can be accomplished with incomplete phase retrieval. Additionally, we show how some phase retrieval can still be achieved in the partial-deconvolution regime and how this allows for additional information in scintillation-based data products, like the dynamic wavefield power, compared to what can be found in traditional dynamic spectra. An examination of dynamic wavefield phase as a function of observing frequency reveals more complete phase retrieval is achieved the closer one gets to the full-deconvolution regime, agreeing with the expectations of cyclic merit. While we demonstrate that fragmentary recovery of the secondary wavefield can be accomplished in the partial-deconvolution regime, we advocate for a synergistic approach with phase retrieval methods like theθ−θtransform, although we also provide discussion about shortcomings of this strategy. Finally, we use the combination of modest cyclic merit and lack of discernible results for PSR J1903+0327 to motivate the creation of an updated “cyclic merit 2.0,” which relies on scintillation bandwidth instead of observing bandwidth. 
    more » « less
    Free, publicly-accessible full text available August 20, 2026
  2. Abstract We use cyclic spectroscopy to perform high-frequency resolution analyses of multihour baseband Arecibo observations of the millisecond pulsar PSR B1937+21. This technique allows for the examination of scintillation features in far greater detail than is otherwise possible under most pulsar timing array observing setups. We measure scintillation bandwidths and timescales in each of eight subbands across a 200 MHz observing band in each observation. Through these measurements we obtain intra-epoch estimates of the frequency scalings for scintillation bandwidth and timescale. Thanks to our high-frequency resolution and the narrow scintles of this pulsar, we resolve scintillation arcs in the secondary spectra due to the increased Nyquist limit, which would not have been resolved at the same observing frequency with a traditional filterbank spectrum using NANOGrav’s current time and frequency resolutions, and the frequency-dependent evolution of scintillation arc features within individual observations. We observe the dimming of prominent arc features at higher frequencies, possibly due to a combination of decreasing flux density and the frequency dependence of the plasma refractive index of the interstellar medium. We also find agreement with arc curvature frequency dependence predicted by Stinebring et al. in some epochs. Thanks to the frequency-resolution improvement provided by cyclic spectroscopy, these results show strong promise for future such analyses with millisecond pulsars, particularly for pulsar timing arrays, where such techniques can allow for detailed studies of the interstellar medium in highly scattered pulsars without sacrificing the timing resolution that is crucial to their gravitational-wave detection efforts. 
    more » « less
  3. Abstract We present observations and timing analyses of 68 millisecond pulsars (MSPs) comprising the 15 yr data set of the North American Nanohertz Observatory for Gravitational Waves (NANOGrav). NANOGrav is a pulsar timing array (PTA) experiment that is sensitive to low-frequency gravitational waves (GWs). This is NANOGrav’s fifth public data release, including both “narrowband” and “wideband” time-of-arrival (TOA) measurements and corresponding pulsar timing models. We have added 21 MSPs and extended our timing baselines by 3 yr, now spanning nearly 16 yr for some of our sources. The data were collected using the Arecibo Observatory, the Green Bank Telescope, and the Very Large Array between frequencies of 327 MHz and 3 GHz, with most sources observed approximately monthly. A number of notable methodological and procedural changes were made compared to our previous data sets. These improve the overall quality of the TOA data set and are part of the transition to new pulsar timing and PTA analysis software packages. For the first time, our data products are accompanied by a full suite of software to reproduce data reduction, analysis, and results. Our timing models include a variety of newly detected astrometric and binary pulsar parameters, including several significant improvements to pulsar mass constraints. We find that the time series of 23 pulsars contain detectable levels of red noise, 10 of which are new measurements. In this data set, we find evidence for a stochastic GW background. 
    more » « less